AF1026 Vibration Monitor

Features ●High-performance acceleration sensor measures the vibration amplitude of 2 vertical axes ●The latest CPU and power supply solution make the measurement accurate and reliable, and the system run stably ●Built-in IIR digital filter design to eliminate interference more effectively ●Multiple value measurement methods: effective value, peak value, peak-to-peak value ●Multiple output methods: CAN interface, RS485 interface, 4~20mA current, etc. ●Measurement method, output method, product size, etc. can be customized ●SSD detection function can protect wind turbines from vibration damage in a timely manner

Category:

AF1026 Vibration Monitor Features ●High-performance acceleration sensor measures the vibration amplitude of 2 vertical axes ●The latest CPU and power supply solutions make the measurement accurate and reliable, and the system runs stably ●Built-in IIR digital filter design to eliminate interference more effectively ●Multiple value measurement methods: effective value, peak value, peak-to-peak value ●Multiple output methods: CAN interface, RS485 interface, 4-20mA current, etc. ●Measurement method, output method, product size, etc. can all be customized ●SSD detection function can protect wind turbines from vibration damage in a timely manner Product Introduction AF1026 is dedicated to real-time monitoring of low-frequency vibrations of wind turbine towers, blade edges, gearboxes, drive shafts and other parts, timely predicting vibration hazards and ensuring safe operation of generator sets. For more product information, please refer to the relevant parameters below. Technical Parameters

Vibration Measurement
sensor
1-X axis,2-Y axis
Range
0~10m / s2
Resolution
0.01m / s2
Accuracy level
2.0 level,The maximum absolute error is±0.20m / s2
Measurement value
RMS, peak, or peak-to-peak value of the original and filtered amplitudes
Effective value measurement
Average time:0.001~5.00s
Peak measurement
Rise time:0.001~1.00s,Decay Time:0.001~100.00s
Digital filtering
type
IIR Bandpass filters can be enabled or disabled individually
bandwidth
0~50Hz,The upper and lower passband cutoff frequencies are configurable
Output method
CAN interface
CANopen protocol
RS485 interface
ModBus protocol
4~20mA Current
3 channels, including X-axis, Y-axis filtered values and SSD detection values
RS232 interface
ModBus protocol, used to connect to PC for parameter configuration and system testing
Security protection
SSD Detection
X-axis, Y-axis raw magnitude vector and
SSD Hazard protection
Relay J3 disconnected
Vibration amplitude exceeds limit
X-axis, Y-axis Amplitude over-limit judgment after filtering,J1、J2 disconnect
Vibration amplitude dangerous protection
Relay J3 corresponds to the X-axis, Y-axis and SSD over-limit disconnection
System error protection
Relay J4 disconnection
Limit and error warnings
Indication via LED lighting
Power consumption
Voltage and power consumption
24V,<10W
shape
L * W * H
250mm* 130mm*55mm , Hard aluminum alloy
temperature
Operating temperature
-40℃~+70℃
Available Models
AF1026-AAAB
(Factory Default Settings: AF1026-C IR2)
AAA-Interface Type:C(CANopen)、I (4~20mA)、R(RS485) B-Monitoring points:2(2 Points,Assigned to X axis、Yaxis axis)